EasyManuals Logo
Home>Lenze>DC Drives>EVF9326

Lenze EVF9326 User Manual

Lenze EVF9326
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #197 background imageLoading...
Page #197 background image
Commissioning
Acceleration, deceleration, braking, stopping
Quick stop
6
6.10
6.10.3
6.10-4
EDSVF9333V EN 3.0-06/2005
6.10.3 Quick stop
Quick stop brakes the drive to standstill with the deceleration time set i n
C0105.
ƒ DC-injection braking (GSB) has priority over quick stop.
Codes for parameter setting
Code Possible settings IMPORTANT
No. Name Lenze Selection
C0105 QSP Tif 5.00 0.00 {0.01 s} 999.90 Quick stop deceleration time
z The deceleration time refers to
a speed variation of C0011 ... 0
8.2-25
8.2-48
Via digital signal:
ƒ MCTRL-QSP = HIGH.
ƒ Activating s ignal DCTRL-QSP. The signal can be activated via 3 OR’d
inputs:
Control word CAN-CTRL.B3 from CAN-IN1
Control word AIF-CTRL.B 3 from AIF-IN
Control word C0135.B3
Via keyboard of t he keypad:
For this the key must be assigned with the quick stop function (C0469 = 2):
activates quick stop
restarts the drive
Description
Activation

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze EVF9326 and is the answer not in the manual?