EasyManuals Logo
Home>Lenze>DC Drives>EVF9326

Lenze EVF9326 User Manual

Lenze EVF9326
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #368 background imageLoading...
Page #368 background image
Configuration
Code table
8
8.3
8.3-59
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0906 -199.99 {0.01 %} 199.99
Function block MCTRL
z Display of the signals linked in
C0890, C0891, C0892, C0893,
C0901 and C0903
8.2-25
8.2-48
1 DIS: N-SET
2 DIS: M-ADD
3 DIS: LO-M-LIM
4 DIS: HI-M-LIM
5 DIS: I-SET
6 DIS: BOOST
C0907 0 1
Function block MCTRL
z Display of the signals linked in
C0899, C0900 and C0902
1 reserved
2 DIS: N/M-SWT
3 DIS: QSP
4 DIS: I-LOAD
C0909 speed limit 1
1 +/- 175 %
Speed limitation, function block
MCTRL
z Limitation of direction of
rotation for the speed setpoint
8.2-25
8.2-48
2 0 ... 175 %
3 -175 ... 0 %
C0910
CFG: VP-ADAPT 1006 FIXED100% Selection list 1 Configuration of analog input
signal, function block MCTRL
z Gain adaptation of the speed
controller
z If the gain is varying, join to
CURVE-OUT of FB CURVE
8.2-25
8.2-48
C0911 DIS: VP-ADAPT -199.99 {0.01 %} 199.99 Function block MCTRL
z Display of the signal linked in
C0910
C0912 OV delay time Æ - {1 ms} - Delay time of the pulse release
afteranOUmessage
Æ depending on C0082, C0086,
C0087, C0088, C0089, C0090,
C0091, C0092
A change of one of the codes
resets C0912 to the time of the
selected motor
z Thetimeisderivedfromthe
double rotor time constant
8.2-25
8.2-48
9.4-3
C0913
OV handling 0 Value of the motor current during
the flying restart process or after
an OU message
z When C0913 = 1, the motor is
driven with reduced current to
the setpoint speed during the
flying restart process of after
an OU message.
z The setting is only effective for
the drives EVF9326 ... EVF9333
8.2-25
8.2-48
0 inactive Non-reduced motor current
1 active Reduced motor current
C0940 Numerator 1 -32767 {1} 32767 Configuration of conversion
factor with numerator and
denominator, function block
CONV1
See System
Manual
(extension)
C0941 Denominator 1 1 {1} 32767
OUT [%] = IN [%]
C0940
C0941
C0942
CFG: IN 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block CONV1
C0943 DIS: IN -199.99 {0.01 %} 199.99 Function block CONV1
z Display of the signal linked in
C0942

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze EVF9326 and is the answer not in the manual?

Lenze EVF9326 Specifications

General IconGeneral
BrandLenze
ModelEVF9326
CategoryDC Drives
LanguageEnglish