Configuration
Code table
8
8.3
8.3-40
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0680 Function 1
1 IN1=IN2
Function selection, function block
CMP1
z Compare input signals at
CMP1-IN1 and CMP1-IN2
See System
Manual
(extension)
2 IN1>IN2
3 IN1<IN2
4 |IN1IN2|
5 |IN1IN2|
6 |IN1IN2|
C0681 HYSTERESIS 1.00 0.00 {0.01 %} 100.00 Hysteresis, function block CMP1
z Hysteresis for input signals
which are not stable and hence
the output oscillates
C0682 Window 1.00 0.00 {0.01 %} 100.00 Window, function block CMP1
z Set the range in which the
signal comparison is to be
apply
C0683
Selection list 1 Configuration of analog input
signal, function block CMP1
1 CFG: IN 5001 MCTRL-NACT CMP1-IN1
2 CFG: IN 19500 FCODE-17 CMP1-IN2
C0684 -199.99 {0.01 %} 199.99 Function block CMP1
z Display of the signals linked in
C0683
1 DIS: IN CMP1-IN1
2 DIS: IN CMP1-IN2
C0685 Function 1
1 IN1=IN2
Function selection, function block
CMP2
z Compare input signals at
CMP2-IN1 and CMP2-IN2
See System
Manual
(extension)
2 IN1>IN2
3 IN1<IN2
4 |IN1IN2|
5 |IN1IN2|
6 |IN1IN2|
C0686 HYSTERESIS 1.00 0.00 {0.01 %} 100.00 Hysteresis, function block CMP2
z Hysteresis for input signals
which are not stable and hence
the output oscillates
C0687 Window 1.00 0.00 {0.01 %} 100.00 Window, function block CMP2
z Set the range in which the
signal comparison is to be
apply
C0688
Selection list 1 Configuration of analog input
signal, function block CMP2
1 CFG: IN 1000 FIXED0% CMP2-IN1
2 CFG: IN 1000 FIXED0% CMP2-IN2
C0689 -199.99 {0.01 %} 199.99 Function block CMP2
z Display of the signals linked in
C0688
1 DIS: IN CMP2-IN1
2 DIS: IN CMP2-IN2