Configuration
Code table
8
8.3
8.3-47
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0751 DFRFG1 TIR 1.000 0.001 {0.001
s}
999.999 Acceleration time T
ir
, function
block DFRFG1
8.2-13
C0752 MAX SPEED 3000 1 {1 rpm} 16000 Maximum speed, function block
DFRFG1
z Maximum speed-up (speed)
C0753 DFRFG1 QSP 0.000 0.000 {0.001
s}
999.900 Deceleration time T
if
for quick
stop, function block DFRFG1
C0754 PH ERROR 2
.
10
9
10 {1} 2
.
10
9
Following error, function block
DFRFG1
z Maximum permissible phase
difference between setpoint
an actual phase
z 1 rev. = 65535 inc
C0755 SYN WINDOW 100 0 {1 inc.} 65535 Synchronisation window,
function block DFRFG1
z 1 rev. = 65535 inc
C0758
CFG: IN 1000 FIXEDPHI-0 Selection list 4 Configuration of input signal,
function block DFRFG1
z Speed/phase setpoint signal
8.2-13
C0759
cfg: qsp 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block DFRFG1
z HIGH = quick stop active
C0760
cfg: stop 1000 FIXED0 Selection list 2 Configuration of input signal,
function block DFRFG1
z HIGH = Status of the profile
generator is maintained,
setpoint is saved
C0761
CFG: RESET 1000 FIXED0 Selection list 2 Configuration of input signal,
function block DFRFG1
z HIGH = resetting the
integrators
C0764 0 1
Function block DFRFG1
z Display of the signals linked in
C0759, C0760 and C0761
1 DIS: QSP
2 DIS: STOP
3 DIS: RESET
C0765 DIS: IN -32767 {1 rpm} 32767 Function block DFRFG1
z Display of the signal linked in
C0758
C0770
CFG: D 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block FLIP1
See System
Manual
(extension)
C0771
CFG: CLK 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block FLIP1
z Each LOW-HIGH edge at
FLIP1-CLK switches the signal
at FLIP1-D to FLIP1-OUT
C0772
CFG: CLR 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block FLIP1
z Resets the flip-flop
z HIGH: Sets FLIP1-OUT = LOW
z Inputhashighestpriority
C0773 0 1
Function block FLIP1
z Display of the signals linked in
C0770, C0771 and C0773
1 DIS: D
2 DIS: CLK
3 DIS: CLR