EasyManuals Logo
Home>Lenze>DC Drives>EVF9326

Lenze EVF9326 User Manual

Lenze EVF9326
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #346 background imageLoading...
Page #346 background image
Configuration
Code table
8
8.3
8.3-37
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0603 Function 1
0 OUT = IN1
Function selection, function block
ARIT3
See System
Manual
(extension)
1 OUT=IN1+IN2
2 OUT = IN1 - IN2
3 OUT=IN1*IN2
4 OUT = IN1 / IN2
5 OUT = IN1 / (100 - IN2)
C0604
Selection list 1 Configuration of analog input
signal, function block ARIT3
1 CFG: IN 1000 FIXED0% ARIT3-IN1
2 CFG: IN 1000 FIXED0% ARIT3-IN2
C0605 -199.99 {0.01 %} 199.99 Function block ARIT3
z Display of the signals linked in
C0604
1 DIS: IN ARIT3-IN1
2 DIS: IN ARIT3-IN2
C0608
CFG: IN 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block SQRT1
See System
Manual
(extension)
C0609 DIS: IN -199.99 {0.01 %} 199.99 Function block SQRT1
z Display of the signal linked in
C0608
C0610
Selection list 1 Configuration of analog input
signals, function block ADD1
See System
Manual
(extension)
1 CFG: IN 1000 FIXED0% Addition input ADD1-IN1
2 CFG: IN 1000 FIXED0% Addition input ADD1-IN2
3 CFG: IN 1000 FIXED0% Subtraction input ADD1-IN3
C0611 -199.99 {0.01 %} 199.99 Function block ADD1
z Display of the signals linked in
C0610
1 DIS: IN ADD1-IN1
2 DIS: IN ADD1-IN2
3 DIS: IN ADD1-IN3
C0612
Selection list 1 Configuration of analog input
signals, function block ADD2
See System
Manual
(extension)
1 CFG: IN 1000 FIXED0% Addition input ADD2-IN1
2 CFG: IN 1000 FIXED0% Addition input ADD2-IN2
3 CFG: IN 1000 FIXED0% Subtraction input ADD2-IN3
C0613 -199.99 {0.01 %} 199.99 Function block ADD2
z Display of the signals linked in
C0612
1 DIS: IN ADD2-IN1
2 DIS: IN ADD2-IN2
3 DIS: IN ADD2-IN3
C0620 DB1 gain 1.00 -10.00 {0.01 } 10.00 Gain, fu nction block DB1
See System
Manual
(extension)
C0621 DB1 VALUE 1.00 0.00 {0.01 %} 100.00 Dead band, function block DB1
z Fault signals around the zero
point of the input signal are
set to 0
C0622
CFG: IN 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block DB1
C0623 DIS: IN -199.99 {0.01 %} 199.99 Function block DB1
z Display of the signal linked in
C0622