Configuration
Code table
8
8.3
8.3-12
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0122 OH4 limit 80 45 {1 °C} 85 Configuration of monitoring OH4
z Monitoring of the heatsink
temperature
z Activating monitoring with
C0582
z Temperature in C0122
reached:
– Warning OH4 is initiated
See System
Manual
(extension)
C0125 Baud rate 0
0 9600 baud
LECOM baud rate
z Baud rate for accessory
module 2102
1 4800 baud
2 2400 baud
3 1200 baud
4 19200 baud
C0126 MONIT CE0 3
0 TRIP
Configuration of monitoring C E0
z Error message in case of
communication error AIF
See System
Manual
(extension)
2 Warning
3 Off
C0130 DIS: act Ti Active T
i
times for the speed
setpoint conditioning, function
block NSET
z Display of the additional
acceleration and deceleration
times for the main setpoint
(C0101, C0103)
z Activation via binary coding of
C0788
1 ... C0788
4
See System
Manual
(extension)
0 C12/C13
1 Tir1/Tif1
2 Tir2/Tif2
... ...
14 Tir14/Tif14
15 Tir15/Tif15
C0132
Controller
enable fly delay
Æ 0 {1 ms} 9999 Minimum time f or controller
inhibit with active flying restart
circuit, delays the start of the
flying restart process after
controller enable
Æ depending on C0082, C0086,
C0087, C0088, C0089, C0090,
C0091, C0092
A change of one of the codes
resets C0132 to the minimum
time of the selected motor
z Thetimeisderivedfromthe
double rotor time constant
8.2-25
8.2-48
C0133
RFG fly delay 100 0 {1 ms} 9999 Deceleration of the ramp
function generator after flying
restart process, function block
NSET
z Deceleration time for the ramp
function generator after a
flying restart process
See System
Manual
(extension)
C0134 RFG charac 0
0 Linear linear
characteristic
Ramp function generator
characteristic, function block
NSET
z Characteristic of the main
setpoint
See System
Manual
(extension)
1 S-shaped S-shaped
characteristic