Commissioning
Acceleration, deceleration, braking, stopping
Changing the direction of rotation
6
6.10
6.10.4
6.10-5
EDSVF9333V EN 3.0-06/2005
6.10.4 Changing the direction of rotation
In the basic configurations (C0005) the direction of rotation of the motor is
reversed in a fail-safe way via the X5/E1 and X5/E2 and the function block
R/L/Q. Thus, only t he main setpoint is changed.
The reversing time depends on the ramp times set for the main setpoint or
quick stop.
When the direction of rotation is changed, the drive brakes along the
deceleration ramp (C0013) and accelerates along the acceleration ramp
(C0012) into the other direction of rotation.
Direction of rotation with in-phase connection:
Direction of
rotation
Signal level at
Notes
X5/E1 X5/E2
CCW rotation LOW HIGH
CW rotation HIGH LOW
Quick stop LOW LOW
Unchanged HIGH HIGH z During operation: The direction of
rotation results from the signal
which was active first.
z At mains connection: The
controller activates quick stop
(QSP).