Configuration
Code table
8
8.3
8.3-22
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0325 Vp2 adapt 1.0 0.1 {0.1 } 500.0 Function block PTCTRL1
z Adaptation of gain V
p2
See System
Manual
(extension)
C0326 Vp3 adapt 1.0 0.1 {0.1 } 500.0 Function block PTCTRL1
z Adaptation of gain V
p3
C0327 Set2 adapt 100.00 0.00 {0.01 %} 100.00 Function block PTCTRL1
z Adaptation of setpoint speed
threshold n
set2
z Condition: C0327 > C0328
C0328 SET1 ADAPT 0.00 0.00 {0.01 %} 100.00 Function block PTCTRL1
z Adaptation of setpoint speed
threshold n
set1
z Condition: C0328 < C0327
C0329 ADAPT ON/OFF 0
0 No adaptation of the process
controller
Function block PTCTRL1
z Adaptation On/Off
1 External adaptation via input
2 Adaptation via setpoint
3 Adaptation via control difference
C0332 PCTRL Tir 0 0 {1 s} 10000 Acceleration time T
ir
, function
block PCTRL1
z The acceleration time refers to
a setpoint change of 0 ... 100 %
See System
Manual
(extension)
C0333 PCTRL1 Tif 0 0 {1 s} 10000 Deceleration time T
if
, function
block PCTRL1
z The deceleration time refers to
a setpoint change of 100 % ... 0
C0336 DIS: act Up 0.0 {0.1 } 500.0 Current gain V
p
, function block
PCTRL1
z Read only
See System
Manual
(extension)
C0337 Bi/unipolar 0
Sphere of action, function block
PCTRL1
0 Bipolar z Output value is limited to
-100 ... 100 %
1 Unipolar z Output value is limited to
0 ... 100 %
C0338 ARIT1 FUNCT 1
0 OUT = IN1
Selection of function, function
block ARIT1
See System
Manual
(extension)
1 OUT=IN1+IN2
2 OUT = IN1 - IN2
3 OUT=IN1*IN2
4 OUT = IN1 / IN2
5 OUT = IN1 / (100 - IN2)
C0339
Selection list 1 Configuration of analog input
signals, function block ARIT1
1 CFG: IN 1000 FIXED0% ARIT1-IN1
2 CFG: IN 1000 FIXED0% ARIT1-IN2
C0340 -199.99 {0.01 %} 199.99 Function block ARIT1
z Display of the signals linked in
C0339
1 DIS: IN ARIT1-IN1
2 DIS: IN ARIT1-IN2
C0350 CAN ADDRESS 1 1 {1} 63 Node address of system bus
z Change is effective after
command ”Reset-Node”