EasyManuals Logo
Home>Lenze>DC Drives>EVF9326

Lenze EVF9326 User Manual

Lenze EVF9326
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #331 background imageLoading...
Page #331 background image
Configuration
Code table
8
8.3
8.3-22
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0325 Vp2 adapt 1.0 0.1 {0.1 } 500.0 Function block PTCTRL1
z Adaptation of gain V
p2
See System
Manual
(extension)
C0326 Vp3 adapt 1.0 0.1 {0.1 } 500.0 Function block PTCTRL1
z Adaptation of gain V
p3
C0327 Set2 adapt 100.00 0.00 {0.01 %} 100.00 Function block PTCTRL1
z Adaptation of setpoint speed
threshold n
set2
z Condition: C0327 > C0328
C0328 SET1 ADAPT 0.00 0.00 {0.01 %} 100.00 Function block PTCTRL1
z Adaptation of setpoint speed
threshold n
set1
z Condition: C0328 < C0327
C0329 ADAPT ON/OFF 0
0 No adaptation of the process
controller
Function block PTCTRL1
z Adaptation On/Off
1 External adaptation via input
2 Adaptation via setpoint
3 Adaptation via control difference
C0332 PCTRL Tir 0 0 {1 s} 10000 Acceleration time T
ir
, function
block PCTRL1
z The acceleration time refers to
a setpoint change of 0 ... 100 %
See System
Manual
(extension)
C0333 PCTRL1 Tif 0 0 {1 s} 10000 Deceleration time T
if
, function
block PCTRL1
z The deceleration time refers to
a setpoint change of 100 % ... 0
C0336 DIS: act Up 0.0 {0.1 } 500.0 Current gain V
p
, function block
PCTRL1
z Read only
See System
Manual
(extension)
C0337 Bi/unipolar 0
Sphere of action, function block
PCTRL1
0 Bipolar z Output value is limited to
-100 ... 100 %
1 Unipolar z Output value is limited to
0 ... 100 %
C0338 ARIT1 FUNCT 1
0 OUT = IN1
Selection of function, function
block ARIT1
See System
Manual
(extension)
1 OUT=IN1+IN2
2 OUT = IN1 - IN2
3 OUT=IN1*IN2
4 OUT = IN1 / IN2
5 OUT = IN1 / (100 - IN2)
C0339
Selection list 1 Configuration of analog input
signals, function block ARIT1
1 CFG: IN 1000 FIXED0% ARIT1-IN1
2 CFG: IN 1000 FIXED0% ARIT1-IN2
C0340 -199.99 {0.01 %} 199.99 Function block ARIT1
z Display of the signals linked in
C0339
1 DIS: IN ARIT1-IN1
2 DIS: IN ARIT1-IN2
C0350 CAN ADDRESS 1 1 {1} 63 Node address of system bus
z Change is effective after
command ”Reset-Node”

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze EVF9326 and is the answer not in the manual?

Lenze EVF9326 Specifications

General IconGeneral
BrandLenze
ModelEVF9326
CategoryDC Drives
LanguageEnglish

Related product manuals