Installing the basic device
Basic devices in the power range 0.37 ... 11 kW
Thermally separated mounting (push-through technique)
4
4.1
4.1.2
4.1-2
EDSVF9333V EN 3.0-06/2005
4.1.2 Thermally separated mounting (push-through technique)
For mounting in push-through technique, the drive controller of type
EVF93xx-EV must be used. In addition, the mounting set for push-through
technique is required.
Type Mounting set Type Mounting set
EVF9321-EV,
EVF9322-EV
EJ0036
EVF9323-EV,
EVF9324-EV
EJ0037 EVF9325-EV,
EVF9326-EV
EJ0038
a1a1
c1c1
aa
cc
gg
d1d1
d1d1
dd
b1b1
bb
LL
10
e
f
9300vec115
Fig. 4.1-2 Dimensions for thermally separated mounting 0.37 ... 11 kW
9300 vector Dimensions [mm]
Type a a1 b b1 C c1 d d1 e
1)
f g
EVF9321-EV
EVF9322-EV
112.5 78 385.5 350 60 95.5 365.5 105.5 250 92 6.5
EVF9323-EV
EVF9324-EV
131.5 97 385.5 350 79 114.5 365.5 105.5 250 92 6.5
EVF9325-EV
EVF9326-EV
169.5 135 385.5 350 117 152.5 365.5 105.5 250 92 6.5
1)
For a fieldbus module plugged onto X1, consider mounting space for connecting cables
9300 vector Dimensions [mm]
Type Width Height
EVF9321-EV
EVF9322-EV
82 350
EVF9323-EV
EVF9324-EV
101 350
EVF9325-EV
EVF9326-EV
139 350
Dimensions
Mounting cutout in control