Transfer roll service check
Tray (x) sensor service check
Step Questions / actions Yes No
1 Remove the ITU. See Image transfer unit
(ITU) removalon page 4-44. Check the
contacts between the HVPS and the ITU.
Clean the contacts and recheck.
Does the error recur?
Replace the ITU. See
“Image transfer unit (ITU)
removal” on page 4-44.
Go to step 2.
Problem resolved.
2
Does the new ITU fix the problem Problem resolved. Go to step 3.
3
Turn the printer off, and remove the rear
shield. See “Top cover assembly removal
on page 4-13.
Turn the printer on, and check the cable at
JHVPS1 connector on the controller board
without disconnecting it.
Verify the following voltage values:
Are the values approximately correct?
Replace the HVPS. See
“High-voltage power
supply (HVPS) assembly
removal” on page 4-38.
Replace the controller
board. See Controller
board removal on
page 4-20.
Step Questions / actions Yes No
1 When the printer is in Ready state, pull the
standard tray out. The display should indicate
Tray (x) Missing. Reinsert the tray.
Does the message remain on the display?
Go to step 2. Go to step 4.
JHVPS1
Pin Voltage
7 +3.3 V dc
10 +3.3 V dc
11 +3.3 V dc
13 +24 V dc
14 Ground
16 Ground

Table of Contents

Other manuals for Lexmark C543dn

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lexmark C543dn and is the answer not in the manual?

Lexmark C543dn Specifications

General IconGeneral
BrandLexmark
ModelC543dn
CategoryPrinter
LanguageEnglish

Related product manuals