HDMI-TPS-RX110AY – User's Manual 25
Creating an EDID - Easy EDID Creator
Since above mentioned Advanced EDID Editor needs more complex knowledge about EDID,
Creator it is possible to create custom EDIDs in four simple steps. By clicking on the Create button below
Source panel, Easy EDID Creator is opened in a new window. For more details about EDID Editor please visit
our website (www.lightware.eu) and download EDID Editor user's manual.
EDID Creator window
Create
Control Menu
RS-232
RS-232 tab in Control menu
The following settings and functions are available (both on local and TPS serial ports):
▪ Operation mode: Pass-through, Control, or Command Injection (for more details about serial interface
modes see the Serial Interface section);
▪ Baud rate: 4800, 7200, 9600, 14400, 19200, 38400, 57600, 115200;
▪ Data bits: 8 or 9;
▪ Parity: None, Odd, or Even;
▪ Stop bits: 1, 1.5, or 2;
▪ Command injection: enable or disable;
▪ Command injection port number;
▪
▪ Message sending via serial port;
▪ Reloading factory defaults (see factory default settings in the Factory Default Settings section).
ATTENTION! Operation mode of the local and TPS serial ports can be set together only. It means if you
set the local RS-232 port to Control mode, the TPS serial link will be changed to Control mode either
automatically.
ATTENTION!
settings (baud rate, data bits, e.t.c.) will not be changeable on the receiver side.