Maintenance work on the carrier
7.4 Fuel system
7 - 30 3 302 756 en Maintenance manual
GMK6400
16.11.2018
• (A) – Remove the filter element (2) and the
filter (1).
If necessary, replace any damaged parts.
• (B) – Screw on a new filter (1) and the filter
element (2).
• Close the valve (3) manually.
• Open the valve (1) – lever parallel to the line.
• Operate the pump (3), until the flowing out
of the screw (2) no longer contains any
bubbles.
• Tighten the screw.
• Start the engine and check for leaks.
• Remove the receptacle.
H
If you have used a clean receptacle, you can refill the fuel tank with the
consumable using a filter.
Otherwise dispose of the consumable properly.