Run-in regulations
16.11.2018
Maintenance manual 3 302 756 en 4 - 1
GMK6400
4 Run-in regulations
There are regulations regarding running in individual parts that must be
followed, after:
– First commissioning or
– Replacement of a part or
– General inspection.
This is why you must carry out additional maintenance work on the carrier
and superstructure at specific intervals:
s
Operating
hours
(oper.
hrs.)
Driven km
(mi)
Additional maintenance work on the
CARRIER
after 50
(30)
Tighten the wheel nuts;
à Special torques, p. 10 - 2.
after 150
(95)
Tighten the wheel nuts;
à Special torques, p. 10 - 2.
after 50 Tighten the clips on the coolant hoses;
à Special torques, p. 10 - 2.
after 100 Lubricate the outrigger beams;
à Lubricating the outrigger beams, p. 7 - 132.
during the
first
100
Check the hydraulic oil filter every week, and
change it if necessary;
à Cleaning the magnetic rods, p. 7 - 91,
à Changing the hydraulic oil filter, p. 7 - 103.
after 100 After 1,000
(650)
Change the drive oil;
à p. 7 - 54 for the transfer case,
à p. 7 - 61 for the axle centre drives,
à p. 7 - 64, for the final drives.
after 250 After 2,500
(1,550)
Change the engine oil;
à Engine manufacturer's documentation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK6400 and is the answer not in the manual?

Manitowoc GROVE GMK6400 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK6400
CategoryConstruction Equipment
LanguageEnglish

Related product manuals