Maintenance work on the superstructure
8.7 Hydraulic system
8 - 46 3 302 756 en Maintenance manual
GMK6400
16.11.2018
8.7.5 Cleaning the magnetic rods
Spare parts
and
tools
– Receptacle, about 5 l (1.5 gal); à p. 2 - 4.
Prerequisites – The truck crane must be standing on a level surface.
– The engine must not be running and must be secured against unauthor-
ised use; Ã p. 2 - 3.
– During the first 100 operating hours: Clean the magnetic rods weekly.
Designation Quantity GROVE part no.
For oil filter 1:
Filter 1 03325700
Packing set 1 03135853
For oil filter 2:
Filter 1 03317083
Cover gasket 1 01372280
O
Risk of environmental damage due to leaking consumables!
Always let consumables drain into suitable receptacles. Wipe up any
consumables that escape.
Store/dispose of consumables and any soaked equipment properly.
Ask about the applicable regulations.