Maintenance work on the carrier
7.3 Engine
7 - 20 3 302 756 en Maintenance manual
GMK6400
16.11.2018
7.3.7 Have the radiator checked/cleaned
Reducing the
interval
• Under difficult operating conditions – at extremely sandy or dusty loca-
tions or if there is a heavy density of fallen leaves – you must have the
radiator fins cleaned earlier than this.
Prerequisites – The truck crane must be supported on outriggers and must be level;
à Operating manual.
– The main boom is fully retracted and raised to 75°; à Operating manual.
– The engine must not be running and must be secured against unauthor-
ised use; à p. 2 - 3.
– The working area on the carrier above the engine covers and between the
radiator units must be freely accessible.
– Trained repair crew and repair tools must be available.
Check the level
of
dirt
M 12