Maintenance work on the carrier
7.6 Transmission
16.11.2018
Maintenance manual 3 302 756 en 7 - 45
GMK6400
7.6.4 Changing the oil and oil filter – Transmission
Oil, spare parts
and tools
– Receptacle, about 30 l (8 gal); à p. 2 - 4.
– Torque wrench for a torque of 60 Nm (44.2 lbf ft).
Prerequisites – The Intarder has not been actuated before checking the oil level (lever on
the steering column).
– The gear oil must be at operating temperature (70 to 95 °C (160 to 200 °F)).
– The truck crane must be raised on outriggers or parked over an inspec-
tion pit.
– The truck crane must be level.
– The engine must not be running and must be secured against unauthor-
ised use; à p. 2 - 3.
s
Y 3
Gear oil
in litres (gal)
Specifications
Classification
GROVE part no.
without Intarder
15 (4.0)
with Intarder
25 (6.6)
ZF TE-ML02
Ecofluid M ZF
synthetic
03325153
Designation Quantity GROVE part no.
Transmission without Intarder:
O-ring 21 x 2 2 04155708
Transmission with Intarder:
O-ring 21 x 2 2 04155708
Oil filter 1 04155134
O-ring 70 x 3 1 04155135
Magnet 1 04159255

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK6400 and is the answer not in the manual?

Manitowoc GROVE GMK6400 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK6400
CategoryConstruction Equipment
LanguageEnglish

Related product manuals