Maintenance work on the carrier
7.14 Hydraulic system
16.11.2018
Maintenance manual 3 302 756 en 7 - 99
GMK6400
7.14.7 Changing the hydraulic oil
The oil only needs to be changed if the laboratory analysis indicates the
need for this;
à Determining the quality of the oil, p. 7 - 97.
Oil, spare parts,
tools
– Connecting piece and hose (toolbox).
– One or more receptacles, about 230 l (61 gal); à p. 2 - 4.
Prerequisites – The outriggers are retracted; à Operating manual.
– The engine must not be running and must be secured against unauthor-
ised use; à p. 2 - 3.
Closing the valves
• Remove the linchpins (2) from the levers (1).
• Close the valves – lever (1) at right angles to
the line.
s
Hydraulic oil
in litres (gal)
Designation
to DIN 51502
Specifications
Classification
GROVE part no.
230 (61) HVLP DIN 51524-3
Viscosity: ISO-VG 32
04162158
Castrol Hyspin
AWH-M 32
Designation Quantity GROVE part no.
Cover gasket 140 / 90 x 3 1 02313899
S
Risk of damage to the hydraulic pumps!
Be sure to secure the engine against unauthorised use.
The hydraulic pumps will be damaged if the engine is started while the
valves in the suction line are closed!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK6400 and is the answer not in the manual?

Manitowoc GROVE GMK6400 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK6400
CategoryConstruction Equipment
LanguageEnglish

Related product manuals