Maintenance work on the superstructure
8.6 Pump transfer case
16.11.2018
Maintenance manual 3 302 756 en 8 - 37
GMK6400
8.6.4 Changing the oil
Oil, spare parts,
tools
– Receptacle, about 5 l (1.3 gal).
Prerequisites – The truck crane must be level.
– The engine must not be running and must be secured against unauthor-
ised use; à p. 2 - 3.
Changing the oil
s
M 12
Gear oil
in litres (gal)
Designation
to DIN 51502
Specifications
Classification
GROVE part no.
4.6 (1.2) Omala S4 GX 150 03143502
Designation Quantity GROVE part no.
Gasket 21 x 26 Cu DIN 7603 2 00117141
G
Risk of scalding from gear oil at operating temperature!
You could scald yourself by gear oil escaping in an uncontrolled manner at
operating temperature. Wear appropriate protective gloves and take care
not to come into contact with the gear oil.
O
Risk of environmental damage due to leaking consumables!
Always let consumables drain into suitable receptacles. Wipe up any
consumables that escape.
Store/dispose of consumables and any soaked equipment properly.
Ask about the applicable regulations.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK6400 and is the answer not in the manual?

Manitowoc GROVE GMK6400 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK6400
CategoryConstruction Equipment
LanguageEnglish

Related product manuals