FPΣ
High-speed Counter and Pulse Output Functions
6-22
6.4.3 I/O Allocation
Double pulse input driver (CW pulse input and CCW pulse input method)
Two output contact are used as a pulse output for “CW, CCW”.
TheI/O allocation of pulseoutput terminal and home inputis determined by thechannel
used. (See the table of specifications on page 6 - 6.)
Set the control code for F171 (SPDH) instruction to “CW/CCW”.
X2
X3
Y0
Home input
Near home
input
CW output
*
Y1
CCW output
Driver
When using CH0
* X3 or other desired input can
be specified for the near home input.
Figure 87: FPΣ Pulse output function -
I/O allocation when using CH0
(double pulse input)
X5
X6
Y3
Home input
Near home
input
CW output
*
Y4
CCW output
Driver
When using CH2
* X6 or other desired input can
be specified for the near home input.
Figure 88: FPΣ Pulse output function - I/O allocation
when using CH2 (double pulse input)
Single pulse input driver (pulse input and directional switching input method)
One output point is used as a pulse output and the other output is used as a direction
output.
The I/O allocation of pulse output terminal, direction output terminal, and home input
is determined by the channel used. (See the table of specifications on page 6 - 6.)
Near home input is substituted by allocating the desired contact and turning on and off
the specified bit of special data register DT90052.
Up to two driver systems can be connected.
X2
X3
Y0
Home input
Near home
input
Pulse output
*
Y1
Directional
switching
output
Driver
When using CH0
* X3 or other desired input can
be specified for the near home input.
Figure 89: FPΣ Pulse output function -
I/O allocation when using CH0
(single pulse input)
X5
X6
Y3
Home input
Near home
input
Pulse output
*
Y4
Directional
switching
output
Driver
When using CH2
* X6 or other desired input can
be specified for the near home input.
Figure 90: FPΣ Pulse output function -
I/O allocation when using CH2
(single pulse input)

Table of Contents

Other manuals for NAiS FP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAiS FP Series and is the answer not in the manual?

NAiS FP Series Specifications

General IconGeneral
BrandNAiS
ModelFP Series
CategoryController
LanguageEnglish

Related product manuals