EasyManuals Logo
Home>Omron>Inverter>M1 Series

Omron M1 Series User Manual

Omron M1 Series
808 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #315 background imageLoading...
Page #315 background image
Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
d08
Speed Control 1 Notch
Filter Attenuation Lev-
el
0 to 40 dB
0
Availa-
ble
dB
page
6-26
d09
Speed Control Jog-
ging Speed Command
Filter
0.000 to 5.000 s
0.02
Availa-
ble
s
page
5-60
d10
Speed Control Jog-
ging Speed Detection
Filter
0.000 to 0.100 s
0.005
Availa-
ble
s
page
5-60
d11
Speed Control Jog-
ging P Proportional
Gain
0.1 to 200.0
10
Availa-
ble
-
page
5-60
d12
Speed Control Jog-
ging I Integral Time
0.001 to 9.999 s
999: Cancel integral term
0.1
Availa-
ble
s
page
5-60
d13
Speed Control Jog-
ging Output Filter
0.000 to 0.100 s
0.002
Availa-
ble
s
page
5-60
d14
Input Terminal [PIA]
[PIB] Pulse Input For-
mat Selection
0: Pulse train signing/pulse
train input
1: Forward/reverse rotation
pulse
2: Quadrature A/B signal (B
phase lead)
3: Quadrature A/B signal (A
phase lead)
2 - -
page
6-11
page
7-145
d15
Input Terminal [PIA]
[PIB] Encoder Pulse
Resolution
20 to 60000
1024 - -
page
6-11
page
7-145
d16
Input Terminal [PIA]
[PIB] Pulse Scaling
Factor Denominator
1 to 32767
1
Availa-
ble
-
page
6-11
page
7-145
d17
Input Terminal [PIA]
[PIB] Pulse Scaling
Factor Numerator
1 to 32767
1
Availa-
ble
-
page
6-11
page
7-145
4 Parameter List
4-149
M1 Series Standard Type User's Manual (I669)
4-2 List of Parameters by Group
4
4-2-10 Parameter d (Applied Functions 2)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron M1 Series and is the answer not in the manual?

Omron M1 Series Specifications

General IconGeneral
BrandOmron
ModelM1 Series
CategoryInverter
LanguageEnglish

Related product manuals