EasyManuals Logo
Home>Oracle>Storage>StorageTek SL8500

Oracle StorageTek SL8500 User Manual

Oracle StorageTek SL8500
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #152 background imageLoading...
Page #152 background image
HLI-PRC Addressing Scheme
C-8 StorageTek SL8500 Library Guide
Library 1: LSM 0 to 3
Library 2: LSM 4 to 7
Library 3: LSM 8 to 11
When adding an additional library to a complex, you should add libraries from right
to left (viewed from the CAP-side of the library). Expanding left to right re-numbers
the LSMs requiring you to reconfigure hosts.
Figure C–4 Pass-thru Port Planning Example
1.
Recommended method with the library added to the left which increases the LSM
numbering sequentially
2. Disruptive method, which requires a reconfiguration of LSM numbering.
3. New library
4. Pass-thru-port connecting existing libraries
Drive HLI-PRC Addressing
For drives, the panel value is always equal to 1, the column value is always equal to 0,
and the row value is between 0 and 15.

Table of Contents

Other manuals for Oracle StorageTek SL8500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle StorageTek SL8500 and is the answer not in the manual?

Oracle StorageTek SL8500 Specifications

General IconGeneral
BrandOracle
ModelStorageTek SL8500
CategoryStorage
LanguageEnglish

Related product manuals