1.3 System Overview
Matrix 832 / 832+ Matrix 424
ZONES
Zones on Main Board
8 fully programmable zones (16
using zone doubling option)
4 fully programmable zones (8 using
zone doubling)
Zone Expander (On Board)
8 fully programmable zones on local
plug In expander (16 using zone
doubling option)
8 fully programmable zones on local
plug In expander (16 using zone
doubling option)
MX-RIX with Zone Analyser
8 fully programmable zones on
remote expander (16 using zone
doubling option)
Not Available
Maximum Zones Capacity
32 zones using zone doubling
option and zone expander
24 zones using doubling option and
zone expander
Zone Configurations
1. Normally closed
2. DEOL – 2 end of line resistors
3. Zone doubling – 1 end of line
resistor
1. Normally closed
2. DEOL – 2 end of line resistors
3. Zone doubling – 1 end of line
resistor
Zone Types
1. Entry / Exit
2. Access
3. Immediate
4. Medical
5. Arm
6. Omitted (Bypassed)
7. Fire
8. PA
9. 24hr
10. Key box
11. Shunt keypad
12. Tamper
13. Key switch Latched
14. Key switch Momentary
15. Unused
1. Entry / Exit
2. Access
3. Immediate
4. Medical
5. Arm
6. Omitted (Bypassed)
7. Fire
8. PA
9. 24hr
10. Key box
11. Shunt keypad
12. Tamper
13. Key switch Latched
14. Key switch Momentary
15. Unused
Zone Attributes
1. Chime
2. Test
3. Mask
4. Double knock
5. Normally Open
6. Normally Closed
1. Chime
2. Test
3. Mask
4. Double knock
5. Normally Open
6. Normally Closed
PROGRAMMABLE OUTPUTS
PGM On-Board
Outputs
1. PGM1 – N/O / N/C
2. PGM2 –
(832+) N/O / N/C
(832) Active High / Active Low
3. PGM3 – Active High / Active
Low
4. PGM4 – Active High / Active
Low
1. PGM1 – N/O / N/C
2. PGM2 – Active High / Active Low
3. PGM3 – Active High / Active Low
4. PGM4 – Active High / Active Low
NOTE: Active High switches from 0V to 12V; Active Low switches from 12V to 0V.