7.6.1 System Options 1
Enter BT. To select an option use the > and ? buttons. To change the option, press the C button.
To save the changes press
B. An acceptance tone will be played.
Option Option Off = Alarm LED Off Option On = Alarm LED On Default
1 AC Fail Warning enabled AC Fail Warning disabled Off
2 Battery Monitoring disable Battery Monitoring enable On
3 Link Only NVM Reset Engineer code and link NVM Reset Off
4 No Limit Log and Event Reporting Limit Log and Event Reporting Off
5 Fault indication only in Tel Line fail Alarm & Fault in Tel Line fail Off
6 Global Tamper Alarm at 0V removed Global Tamper Alarm at OV applied Off
7 50Hz AC Frequency 60Hz AC Frequency Off
8 AC Derived Real Time Clock Quartz Derived Real Time Clock Off
7.6.2 System Options 2
Enter BT. To select an option use the > and ? buttons. To change an option press the C button.
To save the changes press
B. An acceptance tone will be played.
Option Option Off = Alarm LED Off Option On = Alarm LED On Default
1 Fault warning On Device Missing Tamper Alarm On Device Missing On
2 Put Zone Restorals In the Log disabled Put Zone Restorals In the Log enabled On
3 Engineer lockout when armed disabled Engineer lockout when armed enabled Off
4 Do not Allow Arm When H, P, I, F, M, T
Zones Open
Allow Arm When H, P, I, F, M, T Zones
Open
On
5 Immediate Zones Open On Exit does not
cause alarm
Immediate Zones Open On Exit cause
alarm
Off
6 Do not Suspend Exit Timer On Open
Zone
Suspend Exit Timer On Open Zone
On
7 Do not enable Bell / Global tamper End
of line
Enable Bell / Global tamper end of line Off
8 Allow Prox user codes whilst armed
enable.
Allow Prox user codes whilst armed
disable.
Off
7.6.3 System Options 3
Enter BTT. To select an option use the > and ? buttons. To change an option press the C button.
To save the changes press
B. An acceptance tone will be played.
Option Option Off = Alarm LED Off Option On = Alarm LED On Default
1 Do not hide display Hide display after 20 seconds of keypad
inactivity
Off *
2 Restore battery faults as they occur Only restore battery faults on exit from
Engineer Mode
Off *
3 Display alarm after first user code entry
(FTA mode)
Display alarm as the alarm occurs Off *
*NOTE: Denmark, Norway, Finland & Sweden – Default option is On.