! Matrix 832 / 832+ / 424
RINS428-5 Page 21
Section 6: Keypad/Reader Symbols & Indications
6.1 The ICON Keypad
Rest of the World Denmark, Norway, Finland & Sweden
Illuminated Correct AC & DC power sources AC power is OK
Blinking Indicates DC source (battery) fault Indicates an AC fault
Extinguished Indicates AC fault / no power to panel No power to the panel
Illuminated OK to Arm, no open zones
Blinking Select partitions to arm or disarm / Programming function is active
Extinguished One or more open zones or all assigned partitions are already armed
Illuminated In Log display qualifies the alarm type / Day mode indicates activated test zone
Slow Blinking Active alarm in FTA mode.
Fast Blinking A latched alarm is active (Denmark, Norway, Finland & Sweden only)
Extinguished No active alarms
Illuminated Indicates a tamper condition (used in log display)
Blinking Indicates a tamper condition in FTA mode
Extinguished No tamper alarm active
Illuminated Indicates a PA alarm condition (used in log display)
Blinking Indicates a PA alarm condition in FTA mode
Extinguished No PA active
Illuminated Indicates a Fire alarm condition (used in log display)
Blinking Indicates a Fire alarm condition in FTA mode
Extinguished No Fire alarm active
Illuminated
Indicates a system Fault
Blinking
Keypad is in Engineer Mode
Extinguished
No Fault active
Illuminated The panel is armed
Blinking Indicates the panel is arming with omitted zones
Extinguished The panel is not armed
Illuminated The panel is disarmed
Blinking Keypad is in user menu mode
Extinguished The panel is not disarmed