7.13 System Timers
PC Programming Procedure
The PC window below shows how to program the system times from the PC software. On the left hand side of
this screen shot is a partition selection box, which should be used to change between desired partitions. 1, 2,
3 and 4. Information in 1 partition can be copied in to other partitions by selecting a partition number in the
partition selection box and pressing the “>>” button. Once all desired attributes have been chosen press
<save> and proceed to the next window.
MEANING
Programmable Options Explanation
Partition Timers
Bell Time - This is the duration of the alarm. It can be set from 2 to 20 minutes or seconds (this depends on
the setting in Partition Options 2, Section 8.10.2).
Entry Time - This is the countdown time that allows the user to enter the premises and disarm the system. It
can be set from 2 to 99 seconds.
Exit Time - This is the countdown time that allows the user to exit the premises before the system arms. It
can be set from 2 to 99 seconds.
Bell Delay - This is a siren activation delay time that can be set from 0 to 99 minutes. However the event will
be reported independently of the bell delay setting.
Final Exit Delay - This is time delay for the last zone to close and can be set from 0 to 99 seconds. This must
be programmed in case one of the arming attributes is set to Final zone, see Section 8.1.
Inactivity Auto Arm - The system can be programmed to auto arm if there is no activity in the premises in
programmable interval of time. It can be set from 0 to 99. After the specified time of inactivity the panel will
arm. This value is in minutes multiplied by 10, so a value of 1 = 10 minutes, 5 = 50 minutes and 99 = 990
minutes. If you set the value to 0 (zero) then this is disabled.