Page 160 RINS428-5
Area 4 = Partition 4 = Common Partition / Area
User Code 13 - MASTER USER - operative in partitions 1, 2, 3, 4
User Code 14 - Temporary Patrol/Cleaner Code - operative only in partition 4
User Code 15 - Duress Code - operative only in partitions 1, 2, 3, 4 and given to all users
User Code 16 - Arm / Disarm Only Code - operative only in partition 4 - given to all department managers to
arm / disarm reception area only
Keypad 4 - Allocated to partitions 1, 2, 3, 4 - Any of the departments could be armed / disarmed by using this
keypad (display system faults, commune)
Proximity Reader - Allocated to partitions 1, 2, 3, 4 - Any of the departments could be armed / disarmed by
using this keypad (commune)
In this example when a user from department 1 comes to work he should first disarm the reception area with
Code 16 (This code normally would be given to department managers only). Then with Code 1, 2, 3 or 4 the
user/s would disarm departments 1, 2, 3, or 4.
13.2 Example 2
The following example represents 3 independent flats with 1 lobby common area.
Area 1 = Partition 1 = Independent
User Code 1 - MASTER USER - operative only in partition 1
User Code 2 - Limited User - operative only in partition 1
User Code 3 - Limited User - operative only in partition 1
User Code 4 - Limited User - operative only in partition 1
User Code 16 - Temporary Cleaner - operative only in partition 1
Keypad 1 - Allocated only to this partition (system faults display, private).
Area 2 = Partition 2 = Independent
User Code 5 - MASTER USER - operative only in partition 2
User Code 6 - Limited User - operative only in partition 2
User Code 7 - Limited User - operative only in partition 2
User Code 8 - Limited User - operative only in partition 2
Keypad 2 - Allocated only to this partition (system faults display, private)
Area 3 = Partition 3 = Independent
User Code 9 - MASTER USER - operative only in partition 3
User Code 10 - Limited User - operative only in partition 3
User Code 11 - Limited User - operative only in partition 3
User Code 12 - Limited User - operative only in partition 3
Keypad 3 - Allocated only to this partition (system faults display, private)
Area 4 = Partition 4 = Common Partition / Area
User Code 1 - MASTER USER - operative only in partition 1
User Code 2-3-4 - Limited User - operative only in partition 1
User Code 16 - Temporary Cleaner - operative only in partition 1
User Code 5 - MASTER USER - operative only in partition 2
User Code 6-7-8 - Limited User - operative only in partition 2
User Code 9 - MASTER USER - operative only in partition 3
User Code 10-11-12 - Limited User - operative only in partition 3
User Code 13 - Duress Code - operative in partitions 1, 2, 3 and 4
User Code 14 - Temporary Cleaner Code - operative only in partition 4
User Code 15 - Temporary Patrol Code - operative only in partition 4
Keypad 4 - Allocated to all partitions - Any of the flats could be armed / disarmed by using this keypad (no
display system faults, commune)
Proximity Reader - Allocated to all partitions - Any of the flats could be armed / disarmed by using this reader
(commune).
When Flats 1, 2, and 3 are all armed in away mode, the lobby / common area will arm automatically.

Table of Contents

Other manuals for Pyronix Matrix 832

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Matrix 832 and is the answer not in the manual?

Pyronix Matrix 832 Specifications

General IconGeneral
BrandPyronix
ModelMatrix 832
CategoryControl Panel
LanguageEnglish

Related product manuals