! Matrix 832 / 832+ / 424
RINS428-5 Page 151
12.12.3 Belle Connection to Matrix 424
+
-
B
AT
+BELL-
Bel l Fuse 1Amp
PGM1
PGM2
PGM3
PGM4
17V AC
Out put
+BAT-
KD Z1
COM
COM
Z2 +AUX- Z3 Z4
RING
TIP
R-1
T-1
17V~
B-
B+
BA
STB
SPARE
BT
TF
BELLE
IMPORTANT
The Belle may be connected / programmed using different
programmable outputs.
In this instance PGM1 is programmed asExternal Bell
and PGM2 is programmed as “Strobe” - See section 4.11
PGM1 = BA = BELL OUTPUT
PGM2 = STB = STROBE TRIGGER
B- B+ BA STB BT TF TAMPER
SPARE
+BAT-
For tamper, BT on the Belle must be connected to a zone
programmed asTamper - in this instance, Z1.