EasyManuals Logo
Home>Pyronix>Control Panel>Matrix 832

Pyronix Matrix 832 Installation Guide

Pyronix Matrix 832
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #69 background imageLoading...
Page #69 background image
! Matrix 832 / 832+ / 424
RINS428-5 Page 63
7.11.2 Partition Options 2
Enter BV followed by one digit for the desired partition number [1 - 4]. To choose an option use the
> and ? buttons. To change an option setting, press the C button. To save the changes press B. An
acceptance tone will be played.
Option Option Off = Alarm LED Off Option On = Alarm LED On Default
1 Bell Time is Minutes Bell Time is Seconds Off
2 Anti-code Reset Disabled Anti-code Reset is Enabled Off
3 Engineer Reset is Disabled Engineer Reset is Enabled Off
4 Reset Required after Confirmed Alarms Reset Required after All Alarms Off
5 Normal Sounder Operation French Sounder Operation Off
6 Do not allow zone restorals after disarm Allow zone restorals after disarm Off
7.12 Arm Options
PC Programming Procedure
The PC window below shows arm options on the PC software. On the left hand side of this screen shot is a
partition selection box, which should be used to change between desired partitions. 1, 2, 3 and 4.
Information in 1 partition can be copied into other partitions by selecting a partition number in the partition
selection box and pressing the “>>” button.
Once all desired attributes have been chosen press <save> and proceed to the next window.
NOTE: There are 5 different exit terminator types for the arm modes A, B, C and D. Each of these arm
modes can be programmed in either Home or Away mode.
Home and Away allocation will also enable programming of partition dependency if more than one
partition is selected.

Table of Contents

Other manuals for Pyronix Matrix 832

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Matrix 832 and is the answer not in the manual?

Pyronix Matrix 832 Specifications

General IconGeneral
BrandPyronix
ModelMatrix 832
CategoryControl Panel
LanguageEnglish

Related product manuals