13.1.5 View FloZone Rates
View Flow Rates
Next
View Station Rates
View FloZone Rates
Done
View FloZone Rates
001 0000.0
FloZone
Max GPM
MV(s) 1
FS (s) 1
1 Turn the controller dial to Flow Sensor
2 At the FLOW SENSOR screen, with Set Flow Rates selected, press Next .
3 At the Set Flow Rates screen, press the
key to select View Flow Rates, then press Next.
4 At the View Flow Rates screen, press the
key to select View FloZone Rates, then press
Next .
5 At the FloZone Flow Rates screen, press the
and keys to select the desired FloZone
number. The MVs and sensors associated with that ow zone are shown below it. The
maximum ow rate for that FloZone will show to the right.
FloZone rates are used by FloManager. The zone rate cannot be set lower than the highest station rate.
13.1.6 Clear Flow Rates
Occasionally it may be desired to clear the previously learned or user entered ow rates and start
over.
Set Flow Rates
Next
Learn Flow
Set Station Rates
Set FloZone Rates
View Flow Rates
Clear Flow Rates
1 At the FLOW SENSOR screen, with Set Flow Rates selected, press Next .
2 At the Set Flow Rates screen, press the
key to select Clear Flow Rates, then press Next.
3 The conrmation screen appears; press Next to clear ow rates.
4 A conrmation screen shows the process is complete.

Table of Contents

Other manuals for Rain Bird LXME2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rain Bird LXME2 and is the answer not in the manual?

Rain Bird LXME2 Specifications

General IconGeneral
BrandRain Bird
ModelLXME2
CategoryController
LanguageEnglish

Related product manuals