13.1.17 Set Flow Units
To use Flo-Manager® or FloWatch™ with the LXME2 controller, you rst need to set the measurement
units for ow management.
1 Turn the controller dial to Flow Sensor
2 At the FLOW SENSOR screen, press the
key to select Set Flow Units, then press Next .
3 At the Set Flow Units screen, press the
and keys to set the desired ow rate (M3/Hr,
Auto, GPM, LPS, or LPM). Then navigate to the Pipe size selection by pressing the key.
4 Press the
and keys to set the desired pipe size measurement (Auto, Inch, or mm).
If Auto is selected, Flow Rate will default to GPM when 60 Hz is detected and to LPS when 50 Hz is detected.
Pipe Size will default to Inches on 60 Hz and to millimetres on 50 Hz.