Image Transfer
D117/D118 4-56 SM
6. Pull out the ITB unit [A] slightly.
7. Remove the ITB unit [A] while holding the right and left guides of the unit.
After replacing the image transfer belt unit
Do the following after replacing the ITB unit.
1. Enter the SP mode.
2. Set SP3-701-018 to “1” (This is the manual setting for the new unit detection).
3. Set SP5-804-022 to “1”, and rotate the ITB for about 100 seconds.
4. Set SP5-804-022 to “0” to stop rotation of the ITB after 100 seconds.
5. Set SP1-001-031 to “1”.