Page #698 background image
Main SP Tables-3
D117/D118 3-196 SM Appendix
023 ML:M *ENG
024 ML:Y *ENG
031 Upper Limit *ENG
Sets sensitivity upper limit using TD
sensor sensitivity calculation.
[0.200 to 0.500 / 0.440 /
0.001-V/wt%/step]
032 Lower Limit *ENG
Sets sensitivity lower limit using TD
sensor sensitivity calculation.
[0.200 to 0.500 / 0.209 /
0.001-V/wt%/step]
033 TC Between H-M *ENG
Sets the TC between H and M using TD
sensor sensitivity calculation.
[1.00 to 10.00 / 2.89 / 0.01wt%/step]
034 TC Between M-L *ENG
Sets the TC between M and L using TD
sensor sensitivity calculation.
[1.00 to 10.00 / 3.00 / 0.01wt%/step]
035 TC Between H-M:K *ENG [1.00 to 10.00 / 2.45 / 0.01wt%/step]
036 TC Between M-L:K *ENG [1.00 to 10.00 / 2.58 / 0.01wt%/step]
3210 [TD.Sens:Vt :Disp]
001 Current: K *ENG
Displays the latest TD sensor output for
each color.
[0.00 to 5.50 / - / 0.01V/step]
002 Current: C *ENG
003 Current: M *ENG
004 Current: Y *ENG
3211 [Vt Limits Err :Disp]
002 Upper Threshold *ENG
Sets Vt upper limit threshold to detect
upper limit error.
[0.00 to 5.00 / 4.70 / 0.01V/step]

Table of Contents

Other manuals for Ricoh MP C305SPF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh MP C305SPF and is the answer not in the manual?

Ricoh MP C305SPF Specifications

General IconGeneral
BrandRicoh
ModelMP C305SPF
CategoryAll in One Printer
LanguageEnglish

Related product manuals