Main SP Tables-2
D117/D118 3-94 SM Appendix
009
Time *ENG [1 to 1440 / 300 / 1minute/step]
Adjust the time threshold for the line position adjustment (Mode b: adjustment
once). The timing for line position adjustment depends on the combinations of
several conditions.
010
Magnification *ENG [0.00 to 1.00 / 0.10 / 0.01%/step]
Adjusts the magnification threshold for line position adjustment. If the length of
the main scan is changed by this amount since the previous MUSIC, then
MUSIC is done again.
011
Temp. 2 *ENG [0 to 100 / 10 / 1deg/step]
Adjust the temperature change threshold for the line position adjustment
(Mode a: adjustment twice). The timing for line position adjustment depends on
the combinations of several conditions.
012
Time 2 *ENG [1 to 9999 / 600 / 1minute/step]
Adjust the time threshold for the line position adjustment (Mode a: adjustment
twice). The timing for line position adjustment depends on the combinations of
several conditions.
013 Te m p . 3 *ENG [0 to 100 / 100 / 1deg/step]
016 Page: Power ON:BW+FC *ENG [0 to 999 / 200 / 1page/step]
2194
[MUSIC Execution Result]
Line Position Adjustment: Execution Result
001
Ye a r *ENG [0 to 99 / - / 1 year/step]
Displays the year of the last MUSIC execution.
002
Month *ENG [1 to 12 / - / 1 month/step]
Displays the month of the last MUSIC execution.
003
Day *ENG [1 to 31 / - / 1 day/step]
Displays the date of the last MUSIC execution.
004 Hour *ENG [0 to 23 / - / 1 hour/step]