Main SP Tables-7
SM Appendix 3-401 D117/D118
Appendix:
SP Mode
Tables
7803 [PM Counter Display] (Page, Unit, [Color])
031 to
048
Displays the number of revolutions of motors or clutches for each current
maintenance unit.
When a unit is replaced, and SP7804-xxx is executed, the current PM counter
value is moved to the PM Counter - Previous (SP7-906-11 to 20) and is reset to
“0”.
The total number of revolutions made with the last unit replaced can be
checked with SP7-906-11 to 20.
ENG
[0 to 999999999 / - / 1 mm/step]
031 Rotation: PCU: K
032 Rotation: PCU: C
033 Rotation: PCU: M
034 Rotation: PCU: Y
035 Rotation: Development Unit: K
036 Rotation: Development Unit: C
037 Rotation: Development Unit: M
038 Rotation: Development Unit: Y
039 Rotation: Developer: K
040 Rotation: Developer: C
041 Rotation: Developer: M
042 Rotation: Developer: Y
043 Rotation: Image Transfer Belt