SC Tables
D117/D118 6-46 SM
6.1.10 SC8XX: OVERALL SYSTEM
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
816
-00
CTL
Energy saving I/O sub-system error
The energy saving I/O sub-system detects an error.
ï‚§ Controller board defective
1. Replace the controller board.
-02 D sysarch (LPUX_GET_PORT_INFO) error
-07 D sysarch (LPUX_GET_PORT_INFO) error
-08 D sysarch (LPUX_ENGINE_TIMERCTRL) error
-09 D sysarch (LPUX_RETURN_FACTOR_STR) error
-10
to -12
D sysarch (LPUX_GET_PORT_INFO) error
-35 D read () error
-91
to -94
D Sub-system error
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
819
CTL
D
Fatal kernel error
[XXXX]: Detailed error code
Due to a control error, a RAM overflow occurred during system
processing. One of the following messages was displayed on the
operation panel.
ï‚§ System program defective
ï‚§ Controller board defective
ï‚§ Optional board defective
1. Replace controller firmware
[0x6261] HDD defective