SP Mode
Tables
2144
[TM/ID Sensor Check Result]
Displays the maximum result 2 values of the ID sensor check.
Front, Center, Rear: ID sensors for the automatic line position adjustment and
the process control
001 Maximum 2: ID Sensor *ENG
[0.00 to 5.50 / - / 0.01V/step]
005 Maximum 2: Front *ENG
006 Maximum 2: Center *ENG
007 Maximum 2: Rear *ENG
2145
[TM/ID Sensor Check Result]
Displays the minimum result 2 values of the ID sensor check.
Front, Center, Rear: ID sensors for the automatic line position adjustment and
the process control
001 Minimum 2: ID Sensor *ENG
[0.00 to 5.50 / - / 0.01V/step]
005 Minimum 2: Front *ENG
006 Minimum 2: Center *ENG
007 Minimum 2: Rear *ENG
2146
[TM-Sensor Test]
This SP is used to check the TM sensors.
005
Number of Edge
Detection:Front
*ENG
[0 to 16 / - / 1/step]
006
Number of Edge
Detection:Center
*ENG
007
Number of Edge
Detection:Rear
*ENG