SP Mode
Tables
106 High:3rd Temp.:sensor2 *ENG [0 to 250 / 180 / 1deg/step]
1131
[Continuous Print Mode Switch]
Sets the permission for paper to feed.
001 Feed Permit Condition Setting *ENG
[0 to 2 / 0: Productivety Mode /
1/step]
0: Productivety Model
1: Fusing Quality 1
2: Fusing Quality 2
1132
[Maximum Duty Switch]
Switches maximum fixed duty level and power control.
001 Control Method Switch *ENG
[0 or 1 / 1: Power Control / 1/step]
0: Fixed Duty
1: Power Control
003 Power Offset *ENG [-4 to 4 / 0 / 1/step]
012 Voltage Detection *ENG [0.0 to 650.0 / 0.0 / 0.1V/step]
013 Temp.:Threshold Value *ENG [0 to 200 / 0/ 1deg/step]
1133
[Last Paper Heater OFF Control]
Sets the time to start turning off the heater after the last paper has fed.
001
Heater OFF Time:Normal
Speed:FC
*ENG [0 to 20000 / 3662 / 1msec/step]
002
Heater OFF Time:Normal
Speed:BW
*ENG [0 to 20000 / 2632 / 1msec/step]
005
Heater OFF Time:Low
Speed:FC
*ENG [0 to 20000 / 7693 / 1msec/step]
006
Heater OFF Time:Low
Speed:BW
*ENG [0 to 20000 / 5623 / 1msec/step]