Main SP Tables-1
SM Appendix 3-15 D117/D118
SP Mode
Tables
1114
[Heat Storage Status]
Sets the threshold for fusing temperature correction to compensate for heat
accumulated on the pressure roller.
001 Temp.:Threshold:Press *ENG [0 to 200 / 80 / 1 deg/step]
002 Temp.:Threshold:Atmosphere *ENG [0 to 200 / 80 / 1 deg/step]
1115
[Target Temp. Correction]
Corrects the temperature based on the difference in the target temperatures
of the end of the hot roller.
001 Temp.:Delta:End *ENG -
1116 [Heat Storage FB Control]
001
Execution mode *ENG [0 to 2 / 0:OFF / 1/step]
Sets the scope of application for FB control pf the heat accumulated on the
pressure roller.
011
Time Out *ENG [0 to 500 / 10 / 1sec/step]
Sets the time between paper feed starting and temperature correction
starting.
021 to
026
Sets the time until the pressure temperature is acquired from F GATE with
normal speed or low speed.
021
Delay:Standard Speed:FC:1 *ENG [0 to 20000 / 3862 / 1msec/step]
022
Delay:Standard Speed:FC:1 *ENG [0 to 20000 / 2712 / 1msec/step]
025
Delay:Low Speed:FC:1 *ENG [0 to 20000 / 8093 / 1msec/step]
026
Delay:Low Speed:FC:1 *ENG [0 to 20000 / 5783 / 1msec/step]
031
Delay:Standard Speed:FC:2 *ENG [0 to 20000 / 3862 / 1msec/step]
032
Delay:Standard Speed:FC:2 *ENG [0 to 20000 / 2712 / 1msec/step]
035
Delay:Low Speed:FC:2 *ENG [0 to 20000 / 8093 / 1msec/step]