Test pattern check Possible cause/Countermeasure
The sub scan registrations of M,
C, Y, K are shifted.
ï‚§ Defective image transfer belt
ï‚§ Defective drive units
ï‚§ Defective ID sensor
ï‚§ Defective BICU
ï‚§ Incorrect SP value
1. Replace the image transfer belt.
2. Replace the ID sensor.
3. Replace the drum motor.
4. Replace the BICU.
5. Adjust the value with SP2-182-022 to -039.
The skew of M, C, Y, K is
different.
ï‚§ Defective PCDU
ï‚§ Defective laser optics housing unit
ï‚§ Defective BICU
1. Reinstall or replace the PCDU.
2. Perform the color skew adjustment (
p.4-3).
3. Replace the laser optics housing unit.
4. Replace the BICU.
The sub scan lines are shifted.
Shifted lines appear cyclically.
ï‚§ Defective PCDU
ï‚§ Defective drive unit
ï‚§ Drum phase adjustment error
1. Reinstall or replace the PCDU.
2. Check or replace the drive unit.