Bit Switches
SM 5-37 J007/J010/J011
J007/J010
J011
Display Count: Detections of Air Present Before Maintenance
Cleanings
7527 PMT CNT:A:T1 Print Head Tank 1
7528 PMT CNT:A:T2 Print Head Tank 2
7529 PMT CNT:A:T3 Print Head Tank 3
7530 PMT CNT:A:T4 Print Head Tank 4
7531 PMT CNT:A:T5 Print Head Tank 5
7532 PMT CNT:A:T6 Print Head Tank 6
Use this SP to display the number of times air was detected during maintenance
cleaning of the right ink suction vent.
5.3 BIT SWITCHES
Soft bit switches are used to do some basic function settings that determine how the
printer operates. This section describes the functions of these bit switches.
5.3.1 CHANGING BIT SWITCH SETTINGS
1. Push and hold down and for 3 sec. then release to enter the SP mode.
2. Push [#Enter].
3. Select "Engine Mainte."
4. When you see "SP No. 1000", select "5301" then push [#Enter].
5. When you see "ENGINE SW" push [#Enter].
ENG SW #1 00001000
bit0 _
Reading from left to right, the digits represents Bit 7 to 0.
"1" switches a bit ON and "0" sets a bit OFF.
The second line of the display contains the cursor. This tells you which bit is
currently active for selection.
Push [Escape] at any time if you want to return to the previous level.
6. Push
or to position the cursor under the digit of the bit switch that you
want to change.
7. Push
or to display "1" or "0".
8. Push [#Enter] to enable the setting.
9. Push [Escape] until the display returns to "ENGINE MAINTE."
10. Select "3. END" and press [#Enter] to leave the SP mode.
Rev. 09/2008