Commissioning (software)
4.7 Setting up addresses and message frames
SIMOTION D410
114 Commissioning Manual, 02/2012
4.7 Setting up addresses and message frames
Overview
After all SINAMICS components have been configured, addresses must be determined for
the process data exchange between the drive and the controller.
This procedure depends on whether symbolic assignments are used.
With symbolic assignment , the addresses are determined automatically by the
engineering system; refer to section Setting up communication for symbolic assignment
(Page 114)
in the absen
ce of symbolic assignment, addresses must be determined manually; refer to
section Message frame configuration (Page 115)
4.7.1 Setting up communication for symbolic assignment
You can set up communication for symbolic assignment using the following methods:
via the SCOUT menu (in the menu, call "Project" > "Set up communication for symbolic
assignment")
at "Download project to target system"
at "Save project and compile changes"
When you set up communication, the message frames, BICO interconnections, and
addresses are set up for the entire project.
See also
Message frame configuration (Page 115)

Table of Contents

Other manuals for Siemens SIMOTION D410 DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D410 DP and is the answer not in the manual?

Siemens SIMOTION D410 DP Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D410 DP
CategoryControl Unit
LanguageEnglish

Related product manuals