Commissioning (software)
4.14 Optimizing the drive and controller
SIMOTION D410
Commissioning Manual, 02/2012
143
The following measuring functions are available:
Setpoint jump at current controller
Reference frequency response at current controller
Setpoint jump at speed controller
Interference jump at speed controller
Reference frequency response at speed controller
Interference frequency response at speed controller
Speed-controlled system (excitation at current setpoint filter)
Additional references
For additional information about drive optimization, consult the
SINAMICS S120
Commissioning Manual.
More detailed information on trace and measuring functions, as well as on the function
generator, can be found in the
SIMOTION SCOUT online help
.
4.14.5 Manual speed controller optimization
Prerequisite
You have already created a project and configured an axis and a drive. You can now
optimize the speed controller.
Procedure
1. Open the project and enter online mode.
2. Click
to call the "Measuring Functions" dialog.
3. Select the drive unit and the drive.

Table of Contents

Other manuals for Siemens SIMOTION D410 DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D410 DP and is the answer not in the manual?

Siemens SIMOTION D410 DP Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D410 DP
CategoryControl Unit
LanguageEnglish

Related product manuals