Commissioning (software)
4.12 Creating a DMC20/DME20
SIMOTION D410
136 Commissioning Manual, 02/2012
4.12.1 Hub properties
DRIVE-CLiQ hub characteristics
The DMC20 and DME20 DRIVE-CLiQ hub modules are used to implement point-to-point
distribution of a DRIVE-CLiQ line. With the DMC20/DME20, an axis grouping can be
expanded with four DRIVE-CLiQ sockets for additional subgroups.
DMC20 is the hub for the control cabinet configuration
DME20 is the hub for use without a control cabinet (IP67 degree of protection).
The modules are especially suitable for applications which require DRIVE-CLiQ nodes to be
removed in groups, without interrupting the DRIVE-CLiQ line and therefore the data
exchange.
Application examples
Encoder expansion and hot-plugging are typical applications implemented by means of a
DRIVE-CLiQ hub.
An encoder expansion involves integration of direct measuring systems. These are
installed in the control cabinet directly at the machine. Several encoders can be
connected to the same hub.
Note:
The SIMOTION D410 has precisely one DRIVE-CLiQ interface. You can use the
DMC20/DME20 to evaluate the motor encoder and an additional encoder by means of
SMx.
Hot plugging is the option for changing motor components while in operation. These
components are connected to a star topology using a DRIVE-CLiQ hub. This setup allows
their deactivation without impairing downstream components.
Additional references
Additional information on the DMC20/DME20 DRIVE-CLiQ hub is contained in the
SIMOTION D410
Manual
SINAMICS S120 Control Units and Supplementary System Components
Manual
4.12.2 Creating a DRIVE-CLiQ hub
The hub is not wired when you insert the DMC20/DME20 and is displayed in the topology
tree in the component storage. The hub has to be wired manually. Proceed as follows:
1. Right-click the "Topology" entry in the Project Navigator.
2. Select the "Insert new object" > "DRIVE-CLiQ Hub" command from the shortcut menu
and confirm with "OK".

Table of Contents

Other manuals for Siemens SIMOTION D410 DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D410 DP and is the answer not in the manual?

Siemens SIMOTION D410 DP Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D410 DP
CategoryControl Unit
LanguageEnglish

Related product manuals