Commissioning (software)
4.10 Configuring drive-related I/Os (with symbolic assignment)
SIMOTION D410
126 Commissioning Manual, 02/2012
Procedure
The configuration of the I/Os is divided into two basic steps:
1. Configuring I/O terminals (Page 127)
The functionality of an I/O channel is configured
(e.g. configuration of a DI/DO as digital
output)
2. Configuring technology objects
and I/O variables (Page 129)
The access of technology objects and I/O variables to I/Os is configured.
The configuration is performed symbolically, whereby only "function-compatible" I/O
channels are offered for selection.
Example:
For the TO measuringInput, only symbolic assignments of the type MI (measuring input)
are offered for selection.
The required message frames and the interconnection are then set automatically by the
engineering system.