Commissioning essentially comprises:
● Checking the scale construction
● Specifying the parameters
● Calibration
● Verifying the envisaged functionality
The electronic weighing system described here is provided with factory-set parameters. The
parameters have been provided for a typical 100 kg scale based on three load cells.
Parameters which can be entered in % or time are preset in such a way that they provide
good results for most applications.
With these default parameters, commissioning can be carried out in 5 minutes (see chapter
5-minute quick start with the operator panel and the Ready-for-Use software (Page 32)).
The following options are available for commissioning the electronic weighing system:
● Operator panel via SIMATIC CPU
● SIWATOOL
If the SIWAREX is only connected to the ET 200SP station, commissioning of the scale can
be carried out using the SIWATOOL program. Operator panel and automation system are
unnecessary. In the event of a fault, additional SIWATOOL diagnostics functions enable fast
analysis of the cause.