Scale parameters and functions
8.12 DR 15 manual tare specification
SIWAREX WP321
Manual, 07/2014, A5E33715669A-02
73
DR 15 manual tare specification
Data recorder DR 15 is used for an external specification of a tare weight.
● Enter the tare weight
● Transfer the data record to the scale
● Enable the tare weight using command 1013
Table 8- 10 Assignment of data record 15
Data record
number
Contains no.
of data rec-
ord
USHORT 2 r 15 - -
Length Data record
length infor-
mation
USHORT 2 r 16 - -
Application Information
about which
application
the DR be-
longs to
USHORT 2 r 201 - -
Version iden-
tifier
Information
on the cur-
rent data
record ver-
sion
USHORT 2 r 1 1 65 635
Specification
of tare weight
(Page 73)
Tare specifi-
cation
memory
(manual tare
value)
FLOAT 4 rw 0 0 Depends on
specification
in DR 3
Reserve Reserve FLOAT 4 rw 0 0 -
Specification of tare weight
You can enter a tare weight. If a tare weight is to be applied, it must be enabled with the
corresponding command. The tare weight must not exceed the maximum tare load specified
in data record DR 3.