Scale parameters and functions
8.6 DR 5 zeroing memory
SIWAREX WP321
Manual, 07/2014, A5E33715669A-02
59
Data record DR 5 displays the current values in the tare memory and the zeroing memory.
● Check all parameters
● Transfer the data record to the scale
Table 8- 3 Assignment of data record 5
Data record
number
Contains no. of data
record
USHORT 2 r 5 - -
Length Data record length infor-
mation
USHORT 2 r 40 - -
Application Information about which
application the DR be-
longs to
USHORT 2 r 201 - -
Version identifi-
er
Information on the cur-
rent data record version
USHORT 2 r 1 1 65 635
Effective tare
weight - from
specification
(Page 60)
Current tare weight from
specification as process
value
FLOAT 4 rw 0 0 Depends
on specifi-
cation in
DR 3
Effective tare
weight (semi-
automatic)
(Page 60)
Current tare weight from
semi-automatic mode as
process value
FLOAT 4 rw 0 0 Depends
on specifi-
cation in
DR 3
Reserve Reserve FLOAT 4 rw 0 - -
Zero weight
(semi-
automatic)
(Page 60)
Current zeroing weight
(affected by zeroing)
FLOAT 4 rw 0 Depends
on specifi-
cation in
DR 3
Depends
on specifi-
cation in
DR 3
Current zero
tracking weight
(Page 60)
Zero point correction
weight affected by auto-
matic zeroing
FLOAT 4 rw 0 Depends
on specifi-
cation in
DR 3
Depends
on specifi-
cation in
DR 3
Dead load
(Page 60)
Dead load determined
during calibration
FLOAT 4 r 0 Depends
on specifi-
cation in
DR 3
Depends
on specifi-
cation in
DR 3
Reserve 1 Reserve SHORT 2 rw 0 - -
Reserve 2 Reserve USHORT 2 rw 0 - -
Reserve 3 Reserve FLOAT 4 rw 0 - -