Scale parameters and functions
8.16 DR 34 ASCII main display value
SIWAREX WP321
Manual, 07/2014, A5E33715669A-02
83
8.16.1
Content of main display as ACII string
The following values can be displayed:
Variable
Command
Switch on increased resolution 701
Current tare weight 705
Gross/net display 710
Net process value 714
Gross process value 715
Serial number 871
Firmware version 875
Below are some display examples. Commands are used to toggle the display values.
The values to be displayed are suppressed if a fault is present.
Value designation
Blank
Display value
Unit of weight
(from DR 3)
N: Net, B/G: Gross,
T: Tare, pT: Preset tare,
S: Sum, ...
Weight
(Tare ≠ 0)
N 2 2 0 , 5 0 •kg•
Neg. weight
(Tare = 0)
B - 0 , 0 3 •t••
Weight in increased resolu-
tion
1 0 , 0 0 3 HIGH
Operator error B I r r o r ****
Tare display activated (pt) p T 5 0 , 5 0 •kg
Tare display activated T 5 0 , 5 0 •kg•

Table of Contents

Other manuals for Siemens SIWAREX WP321

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WP321 and is the answer not in the manual?

Siemens SIWAREX WP321 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WP321
CategoryAccessories
LanguageEnglish

Related product manuals