Scale parameters and functions
8.13 DR 30 current process values
SIWAREX WP321
76 Manual, 07/2014, A5E33715669A-02
The current gross weight. Values are rounded as specified in data record DR 3 with the
"Decimal places for process values" (Page 49) parameter.
The current net weight. Values are rounded as specified in data record DR 3 with the
"Decimal places for process values" (Page 49) parameter.
The current tare weight. Values are rounded as specified in data record DR 3 with the
"Decimal places for process values" (Page 49) parameter.
The current weight for the main display. The resolution corresponds to the scale interval
(Page 49) specified in data record DR 3.
Gross / net weight with increased resolution (x 10)
The current weight for the main display in higher resolution. The resolution corresponds to
the scale interval specified in data record DR 3 x 10.
The current tare weight (scale interval from DR 3). The resolution corresponds to the scale
interval specified in data record DR 3.
Refresh counter for process values
Measured values are calculated every 10 ms in the SIWAREX module. A counter is
incremented by 1 each time. Once the counter reaches the value 65536, it starts again from
zero. The counter can be used as a time stamp for data record DR 30.