Scale parameters and functions
8.11 DR 14 SIMATIC interface parameters
SIWAREX WP321
Manual, 07/2014, A5E33715669A-02
71
DR 14 SIMATIC interface parameters
The parameters which define the response of the SIMATIC interface are specified in data
record DR 14. It is possible to define the process values to be output on the basis of the I/O
area.
● Check the parameters and modify them as required
● Transfer the data record to the scale
Table 8- 8 Assignment of data record 14
Data record
number
Contains no.
of data rec-
ord
USHORT 2 r 14 - -
Length Data record
length infor-
mation
USHORT 2 r 16 - -
Application Information
about which
application
the DR be-
longs to
USHORT 2 r 201 - -
Version iden-
tifier
Information
on the cur-
rent data
record ver-
sion
USHORT 2 r 1 1 65 635
Selection of
process val-
ue 1, 2
(Page 72)
Code for the
selection of
the process
variable to be
updated
USHORT 2 rw 4 0 10
Selection of
process val-
ue 1, 2
(Page 72)
Code for the
selection of
the process
variable to be
updated
USHORT 2 rw 6 0 10
Reserve 1 Reserve SHORT 2 rw 0 0 -
Reserve 2 Reserve USHORT 2 rw 0 0 -